RESPIROMETRÍA ON-LINE
NUEVO MODULO DE CONTROL DE LA EDAD DEL FANGO

SN5- Toxicity Detector

  • flyer_SN5
  • comunicaciones
  • SN-8. Murcia 1
  • sn8
Flyer SN5 english
flyer_SN5 english.pdf (1.54MB)
Flyer SN5 english
flyer_SN5 english.pdf (1.54MB)

In collaboration with its technological partner INCONEF, SENSARA has developed SN5, an online respirometer that can detect toxicity in the influent before it enters the plant. This enables immediate action to prevent the partial or total entry of toxicity in the biological reactor, so preventing this toxicity from inhibiting the process. The mobility of this device enables respirometry readings to be taken quickly in the field.

WHAT MAKES IT SPECIAL?

In just a few minutes it can find out if the influent water that is about to enter the plant will be toxic for the bacteria, so inhibiting their activity.

APPLICATIONS

  • Toxicity detection

PARAMETERS

  • % Inhibición
  • Oxygen, ORP, pH, Rs max.

ADAVANTAGES

  • Low maintenance sensors.
  • Installation at the entrance to the wastewater treatment plant (pretreatment,
    pumping, etc).
  • Configured with MODBUS TCP communication, with 4-20 or 0-10V outputs for integration with the plant’s control system. Remote control. Database. Email alerts. Allows the operator to carry out a bypass or take other steps instantly.

CHARACTERISTICS

  • Touch-screen user interface
  • Software for the automatic calculation of % Inhibition
  • Simple data transfer for PC.
  • Data history.
  • Portable cabinet measuring 400x500mm.

ELECTRICAL AND SOFTWARE SPECIFICATIONS

  • Wifi, Ethernet connection
  • Modbus communication
  • Data registry
  • Trend graphics.
  • Data export.
  • Software for computers.
  • APP for mobile devices.

TECHNICAL SPECIFICATIONS

OXYGEN

  • Range: 0 - 35mg/l.
  • Max. Temp.: 50ºC.
  • 1 or 2 calibration points (air saturation and 0ppm).
  • Response time 0.06 mg/ 1 sec.

PH

  • Range: 0-14 (Na+ error at > 12.3 pH)
  • Temp. range: 1-99ºC (212ºF).
  • Response time: 95% in 1 second.
  • Isopotential point: pH 7.00 (0 mV)

TEMPERATURE

  • Range: -200ºC to 850ºC.
  • Type of sensor: Class A platinum, RTD.
  • Accuracy: +/- (0.15 + (0.002*t)).
  • Response time: 90% in 13s.

REDOX

  • Range: +/- 2000mV.
  • Temperature: 80ºC (176ºF).
  • Response time: 95% in 1 second.
  • Dimensions: 12mm x 150mm (1/2” x 6”).
 
Correo
Llamada
Asignación
LinkedIn