RESPIROMETRÍA ON-LINE
ON LINE RESPIROMETRY

S1-4 MULTIPARAMETRIC MONITOR (PH, Oxígeno, ORP, Conductividad, Turbidity)

The S1-4 Monitor is specially designed to be able to incorporate up to 4 different pH, ORP, conductivity, galvanic oxygen, optical oxygen, turbidity and/or temperature sensors or even 4 of the same kind of sensor.

  • flyer_S1-4MONITOR-v2
  • 20190116_102445
  • 17 (si cambiamos los sensores cambian los botones de calibracion el 1 ha cambiado)
  • 3
  • 18
  • 20

¿What makes it special?

Unlike more traditional devices, the S1-4 contains a simple software which, in addition to the standard functions of configuration and calibration of the sensors, also enables graphics management and export of data to Excel files.

GRAPHICS MANAGEMENT

If the user does not have data in a SCADA, this allows them to find out the parameters of the plant at any time, providing very valuable information about the process.

EXPORT OF DATA TO EXCEL FILES

The S1-4 has a button which enables the user to export to an Excel file the data gathered from all the sensors between two selected dates.

GENERAL CHARACTERISTICS

  • Low maintenance sensors
  • Touchscreen user interface
  • Graphics management software
  • Simple data export for PC
  • Record of data

PHYSICAL CHARACTERISTICS

  • Box with strong walls for control systems in ABS
  • Transparent screen protection cover. Protection category IP 65.
  • Direct assembly on the wall or set of external angle brackets.
  • DIN rails assembly
  • Dimensions: 2957x219x122

ELECTRICAL SPECIFICATIONS

  • 4 - 4-20 outputs.
  • Modbus communication
  • Ethernet connection and USB connection

TECHNICAL SPECIFICATIONS OF THE SENSORS

GALVANIC OXYGEN

  • Range: 0 - 35 mg/1
  • Response time: 0.06 mg/1 second.
  • 1 or 2 calibration points (air saturation and 0 ppm).

OPTICAL OXYGEN

  • Range: 0 - 20 mg/1
  • Accuracy: <5%, or 0.3 NTU.
  • Response time: 40 seconds
  • 1 or 2 calibration points (air saturation and 0 ppm).

PH

  • Range: 0-14 (Na+ error at >12.3pH).
  • Temperature range: 1-99ºC (212ºF).
  • Response time: 95% in 1 sec.
  • Isopotential Point: pH 7.00 (0 mV).

TEMPERATURA

  • Range: -200ºC to 850ºC
  • Type of probe: Class A platinum, RTD
  • Accuracy: +/- (0.15 + (0.002*t)).

REDOX

  • Range: + /-2000Mv.
  • Temperature: 80ºC (176ºF).
  • Response time: 95% in 1 second
  • Dimensions: 12mm x 150mm.

CONDUCTIVIDAD

  • Range: 5 – 200,000 µS/cm
  • Internal sensor temperature: PT1000
  • Temperature: 0 – 110ºC.
  • Response time: 90% in 1 second

TURBIDEZ       

  • Range: 0.1 – 1000 NTU
  • Precision: &lt; 5%, or 0.3 NTU
  • Temperature: 0 – 50ºC
  • Certification IP68 (10m)
 